Skip to content
recurance

Benjamin Wylie

14 Nov 2016 · Coroner Peter Bedford · Berkshire

The coroner's concerns

  1. 1. grease expelled from nipple

    “risk of grease being expelled from the grease nipple at high pressure was recognised”
  2. 2. missing permanent warning plate

    “No permanent warning plate or sign was attached to the machine beside the grease nipple.”
  3. 3. lack of pressure release valve

    “pressure release values within the grease nipple unit that prevents pressure building up”
  4. 4. existing machines lack greasing adaptation

    “new machines allow greasing of the tracks with the plate in place but there are a number of existing machines in use which do not have that adaptation”
  5. 5. absence of warning bulletin

    “no warning bulletin has been issued to existing users of the relevant piling rig machines”

Responses

2016-0407-Response-by-HSE.pdf ↗· Health and Safety Executive

Stated action · currently in draft

“HSE will make mention of this point in its new Safety Alert, currently in draft.”
  • Built with
  • NVIDIA Nemotron Nano, Super and Ultra
  • Nebius Token Factory inference
  • Qwen3 Embedding 8B on Token Factory
  • Tavily follow-up web search
  • Postgres and pgvector search
  • Next.js site

Source: Prevention of Future Deaths reports and responses published by the Courts and Tribunals Judiciary at judiciary.uk. Crown copyright, used under the Open Government Licence v3.0. Data updated 26 Oct 2026.

A link shows that a similar concern was raised again, not why. It is not a finding about any organisation or person. Methodology and responsible use · Report an error